Interface Shear Check Between Girder and Diaphragm as per IRC 112
The interface shear check between the girder and the diaphragm for girder continuity, as per IRC: 112-2020 (Limit State Design), ensures proper shear transfer at the connection. Below is a step-by-step procedure: 1. What is Interface Shear? Interface shear is the shear force transmitted between different structural elements, in this case, between the main girder and … Read more