List of IS codes for Plastic Piping System

IS 4984 (pdf)1995high-density polyethylene pipes for potable water supplies
IS 4985 (pdf)2000Unplasticized PVC Pipes for Potable Water Supplies –
IS 7634-1 (pdf)1975Code of practice for plastic pipes work for potable water supplies, Part 1: Choice of materials and general recommendations
IS 7634-2 (pdf)2012Plastics Pipes Selection, Handling, Storage and Installation for Potable Water Supplies – Code of Practice, Part 2: Laying and jointing of polyethylene (PE) pipes
IS 7634-3 (pdf)2003Plastics Pipe Selection, Handling, Storage and Installation for Potable Water Supplies – Code of Practice : Part 3 – Laying and Jointing of UPVC Pipes
IS 7834-1 (pdf)1987injection moulded PVC socket fittings with solvent cement joints for water supplies, Part 1: General requirements
IS 7834-2 (pdf)1987injection moulded PVC socket fittings with solvent cement joints for water supplies, Part 2: Specific requirements for 45 degrees elbows
IS 7834-3 (pdf)1987injection moulded PVC socket fittings with solvent cement joints for water supplies, Part 3: Specific requirements for 90 degree elbows
IS 7834-4 (pdf)1987injection moulded PVC socket fittings with solvent cement joints for water supplies, Part 4: Specific requirements for 90 degree tees
IS 7834-5 (pdf)1987Injection Moulded PVC Socket Fittings With Solvent Cement Joints for Water Supplies, Part 5: Specific Requirements for 45 degree Tees
IS 7834-6 (pdf)1987injection moulded PVC socket fittings with solvent cement joints for water supplies, Part 6: Specific requirements for sockets
IS 7834-7 (pdf)1987injection moulded PVC socket fittings with solvent cement joints for water supplies, Part 7: Specific requirements for unions
IS 7834-8 (pdf)1987injection moulded PVC socket fittings with solvent cement joints for water supplies, Part 8: Specific requirements for caps
IS 8008-1 (pdf)2003Injection Moulded/Machined High Density Polyethylene (HDPE) Fittings for Potable Water Supplies, Part 1: General Requirements for Fittings
IS 8008-2 (pdf)2003Injection Moulded/Machined High Density Polyethylene (HDPE) Fittings for Potable Water Supplies, Part 2: Specific Requirements for 90° Bends
IS 8008-3 (pdf)2003Injection Moulded/Machined High Density Polyethylene (HDPE) Fittings for Potable Water Supplies, Part 3: Specific Requirements for 90° TEES
IS 8008-4 (pdf)2003Injection Moulded/Machined High Density Polyethylene (HDPE) Fittings for Potable Water Supplies, Part 4: Specific Requirements for Reducers
IS 8008-5 (pdf)2003Injection Moulded/Machined High Density Polyethylene (HDPE) Fittings for Potable Water Supplies, Part 5: Specific Requirements for Ferrule Reducers
IS 8008-6 (pdf)2003Injection Moulded/Machined High Density Polyethylene (HDPE) Fittings for Potable Water Supplies, Part 6: Specific Requirements for Pipe Ends
IS 8008-7 (pdf)2003Injection Moulded/Machined High Density Polyethylene (HDPE) Fittings for Potable Water Supplies, Part 7: Specific Requirements for Sandwich Flanges
IS 8008-8 (pdf)2003Injection Moulded/Machined High Density Polyethylene (HDPE) Fittings for Potable Water Supplies, Part 8: Specific Requirements for Reducing Tees
IS 8008-9 (pdf)2003Injection Moulded/Machined High Density Polyethylene (HDPE) Fittings for Potable Water Supplies, Part 9: Specific Requirements for Ends Caps
IS 8360-1 (pdf)1977fabricated high density polyethylene (HDPE) fittings for potable water supplies, Part 1: General requirements
IS 8360-2 (pdf)1977fabricated high density polyethylene (MDPE) fittings for potable water supplies, Part 2 Specific requirements for 90 degree tees
IS 8360-3 (pdf)1977fabricated high density polyethylene (HDPE) fittings for potable water supplies, Part 3 Specifc requirements for 90 degree bends
IS 9271 (pdf)2004Unplasticized Polyvinyl Chloride (UPVC) Single Wall Corrugated Pipes for Drainage –
IS 10124-1 (pdf)2009Fabricated PVC-U Fittings for Potable Water Supplies – Specification, Part 1: General Requirements
IS 10124-2 (pdf)2009Fabricated PVC-U Fittings for Potable Water Supplies – Specification, Part 2: Specific Requirements for Sockets
IS 10124-3 (pdf)2009Fabricated PVC-U Fittings for Potable Water Supplies – Specification, Part 3: Specific Requirements for Straight Reducers
IS 10124-4 (pdf)2009Fabricated PVC- U Fittings for Potable Water Supplies – Specification, Part 4: Specific Requirements for Caps
IS 10124-5 (pdf)2009Fabricated PVC-U Fittings for Potable Water Supplies – Specification, Part 5: Specific Requirements for Equal Tees
IS 10124-6 (pdf)2009Fabricated PVC-U Fittings for Potable Water Supplies – Specification, Part 6: Specific Requirements for Flanged Tail Pieces with Metallic Flanges
IS 10124-7 (pdf)2009Fabricated PVC-U Fittings for Potable Water Supplies – Specification, Part 7: Specific Requirements for Threaded Adaptors
IS 10124-8 (pdf)2009Fabricated PVC-U fittings for Potable Water Supplies, Part 8: Specific Requirements for 90 degree Bends
IS 10124-9 (pdf)2009Fabricated PVC-U Fittings for Potable Water Supplies – Specification, Part 9: Specific Requirements for 60 o Bends
IS 10124-10 (pdf)2009Fabricated PVC-U Fittings for Potable Water Supplies – Specification, Part 10: Specific Requirements for 45o Bends
IS 10124-11 (pdf)2009Fabricated PVC-U fittings for Potable Water Supplies, Part 11: Specific Requirements for 30 degree Bends
IS 10124-12 (pdf)2009Fabricated PVC-U Fittings for Potable Water Supplies – Specification, Part 12: Specific Requirements for 22 ½o Bends
IS 10124-13 (pdf)2009Fabricated PVC-U Fittings for Potable Water Supplies – Specification Part 13 Specific Requirements for 11¼oBends, Part 12: SPECIFIC REQUIREMENTS FOR 22 ½o BENDS
IS 12231 (pdf)1987Unplasticized PVC Pipes for Use in Suction and Delivery Lines of Agricultural Pump Sets
IS 12235-1 to 19 (pdf)2004Thermoplastics Pipes and Fittings – Methods of Test
IS 12709 (pdf)1994glass-fibre reinforced plastic (GRP) pipes joints and fittings for use for potable water supply
IS 12818 (pdf)2010unplasticized polyvinyl chloride (PVC-U)screen and casing pipes for bore/tubewell
IS 13592 (pdf)1992UPVC pipes for soil and waste discharge systems inside buildings including ventilation and rainwater system
IS 13592 (pdf)2013Unplasticized Polyvinyl Chloride (PVC-U) pipes for soil and waste discharge systems inside buildings including ventilation and rainwater system
IS 13593 (pdf)1992UPVC pipe fittings to be used with the UPVC pipes in the suction and delivery lines of agricultural pumps
IS 13916 (pdf)1994Code of practice for installation of glass fibre reinforced plastic (GRP) piping system
IS 14333 (pdf)1996High density polyethylene pipe for sewerage –
IS 14402 (pdf)1996GRP pipes joints and fittings for use sewerage, industrial waste and water (other than potable)
IS 14735 (pdf)1999Unplasticized Polyvinyl Chloride (UPVC) Injection Moulded Fittings for Soil and Waste Discharge System for Inside and Outside Buildings Including Ventilation and Rain Water System –
IS 14787 (pdf)2000Unplasticized PVC Pipes (Ducts) and Fittings for Underground Telecommunications Cable Installation –
IS 14885 (pdf)2001Polyethylene Pipes for the Supply of Gaseous Fuels –
IS 15265 (pdf)2003Flexible PVC Pipes or Polymer Reinforced Thermoplastic Hoses for Suction and Delivery Lines of Agricultural Pumps – Specification
IS 15328 (pdf)2003Unplasticized Non-Pressure Polyvinyl Chloride ( PVC -U ) Pipes for use in Underground Drainage and Sewerage Systems –
IS 15450 (pdf)2004Polyethylene/ Aluminium/ Polyethylene Composite Pressure Pipes for Hot and Cold Water Supplies –
IS 15778 (pdf)2007Chlorinated polyvinyl chloride (CPVC) pipes for potabvle hot and cold water distribution supplies –
IS 15801 (pdf)2008Polypropylene-random copolymer pipes for hot and cold water supplies –
IS 15927-1 (pdf)2012Polyethylene Fittings for use with Polyethylene Pipes for the Supply of Gaseous Fuels – Specification, Part 1: Fittings for Socket Fusion using Heated Tools
IS 15927-2 (pdf)2012Polyethylene Fittings for use with Polyethylene Pipes for the supply of Gaseous Fuels – Specification, Part 2: Spigot Fittings for Butt Fusion for Socket Fusion using Heated Tools and for use with Electro Fusion Fittings
IS 15927-3 (pdf)2011Polyethylene Fittings for use with Polyethylene Pipes for the Supply of Gaseous Fuels, Part 3: Electro Fusion Fittings
IS 16098-1 (pdf)2013Structured-Wall Plastics Piping Systems for Non-Pressure Drainage and Sewarage – Specification, Part 1: Pipes and Fittings with Smooth External Surface, Type A
IS 16098-2 (pdf)2013Structured-Wall Plastics Piping Systems for Non-Pressure Drainage and Sewarage – Specification, Part 2: Pipes and Fittings with Non-Smooth External Surface, Type B
SP 57 (pdf)1993Handbook on Pipes and Fittings for Drinking Water Supply